Line Fiber Spectrometer

MS2000 high-resolution optical fiber spectrometer

Based on the traditional CT optical path design, professional stray light absorption structure and high-performance plane reflection grating, the optical path stray light is~2 ‰ NA. 0.08 numerical aperture, high resolution, up to 0.07nm Platform-based design, can be configured with 300g/l-2400g/l grating of various specifications

MS2000 is a miniature optical fiber spectrometer designed based on the symmetrical CT optical path. It is compact with a focus of 98mm, and the spectral range can be configured. It uses N.A0.08 numerical aperture, with high resolution, up to 0.1nm; Low stray light,~0.5 ‰. Small temperature drift, suitable for laser measurement, plasma emission spectrum measurement, color measurement, absorbance measurement, Raman measurement and other industrial field measurements. It is an industrial optical fiber spectrometer with high performance and price.

XS11639 High sensitivity optical fiber spectrometer

Platform-based design, which can be configured with 500g/l-2400g/l gratings of various specifications to achieve 190nm-1100nm configurable spectral range Configured with UV enhanced linear array 2048pixel CMOS detector, with strong UV spectral response High-performance AD quantization sampling circuit, CCD quantization background noise ≤ 30RMS (100ms integration time)

XS11639 is a basic optical fiber spectrometer, which adopts cross CT structure design, NA 0.11 numerical aperture, incident focal length 42mm, small size and compact structure. Ultraviolet enhanced CMOS detector is used to optimize the ultraviolet response. Configured with replaceable slit mechanism with key, and optimized slit height design to meet the requirements of high sensitivity sampling. The 24PIN control interface is configured to meet various measurement scenarios such as color measurement, radiation measurement, absorption measurement, fluorescence spectrum, Raman spectrum, etc. It adopts special lens fixing technology and photoelectric separation structure, which has good temperature stability and reliability.

Multi-channel fiber spectrometer

Multi-channel fiber spectrometer High resolution and low signal to noise ratio Stable performance

HRS2048 is a multi-channel fiber spectrometer for narrow linewidth applications that can support up to 8 channels. The spectrometer is equipped with Hamamatsu photon highly sensitive linear array CMOS image sensor, together with the 16-bitA/D sampling module to provide the spectrometer with excellent spectral signal response and extremely wide response range. At the same time, the compact structure design and stable circuit design ensure that HRS2048 has excellent spectral resolution, signal-to-noise ratio and temperature stability. HRS2048 multichannel fiber spectrometer has been widely used in industrial equipment such as laser measurement, radiation measurement, plasma luminescence, elemental analysis and so on.

Miniature visible spectrometer

Small size, overall size72×46×16mm; High integration, can be integrated into the handset Micro optical fiber spectrometer based on MEMS technolog

XS12666 is mainly used in life science, medical diagnosis, solid-state lighting, handheld color monitoring equipment for color management, environmental analysis and other industries. It is a micro optical fiber spectrometer based on MEMS technology. Its optical structure is through semiconducting
Volume technology integration, Hamamatsu c12666ma sensor is used as the detector, and the spectral range is 340-780nm.

SS-VT-1

Optical path design based on traditional CT Wavelength temperature drift < 0.2pixel/ ℃ High performance AD quantization sampling Circuit

SS-VT-1 is a highly integrated spectrometer for measuring visible absorbance and transmittance of liquid samples. The spectrometer integrates the necessary accessories for liquid absorbance or transmittance measurement, detector, light source and sample cell bracket, and is equipped with a highly sensitive linear array CMOS image sensor, together with the 16-bit Ahammer D sampling module to provide the spectrometer with excellent spectral signal response and extremely wide response range. At the same time, the compact structure design and stable circuit design ensure that SS-VT-01 not only ensures the micro size, but also ensures excellent spectral resolution, signal-to-noise ratio and temperature stability.

HS2048

Based on traditional CT optical path design, excellent stray light absorption structure and high performance imported planar reflection grating, light path stray light ~ 2 ‰ Using NA.0.08 numerical aperture, high resolution, the best 0.07nm Platform design, you can configure 500g/l-2400g/l gratings of various specifications

HS2048 is a miniature optical fiber spectrometer based on symmetrical CT optical path, with compact structure, configurable spectral range, high numerical aperture of N.A0.08, high resolution, and low stray light, ~ 2 ‰. With the characteristics of small temperature drift and wavelength temperature drift ~ 0.1pixel/ ℃, it is suitable for many industrial field measurements such as laser measurement, plasma emission spectrum measurement, color measurement, absorbance measurement and Raman measurement. It is an industrial grade optical fiber spectrometer with high performance and price.

HS4096

Based on traditional CT optical path design, professional stray light absorption structure and high performance planar reflection grating, light path stray light ~ 0.2% Using NA.0.08 numerical aperture, high resolution, the best 0.07nm Platform design, you can configure 500g/l-2400g/l gratings of various specifications

HS4096 is a high-resolution micro-fiber spectrometer based on symmetrical CT optical path design, with compact structure and configurable spectral range, using N.A0.08 numerical aperture, high resolution, up to 0.07nm, low stray light, ~ 0.2%. With the characteristics of small temperature drift and wavelength temperature drift ~ 0.2pixel/ ℃, it is equipped with 4096 pixel CMOS detector, low quantization spectral dark noise and more spectral channels, which is suitable for many industrial field measurements such as laser measurement, plasma emission spectrum measurement, color measurement, absorbance measurement and Raman measurement. It is an industrial grade optical fiber spectrometer with high performance and price.

CS100 miniature fiber spectrometer

Stray light ~ 0.2% High resolution, best 0.07nm Wavelength temperature drift ~ 0.1pixel/ ℃

CS100 is a miniature optical fiber spectrometer with compact structure design, configurable spectral range and high equipment resolution, up to 0.07 nm; low stray light, ~ 0.2% stray light, small temperature drift, wavelength temperature drift ~ 0.1pixel/ ℃. It is suitable for laser measurement, plasma emission spectrum measurement, color measurement, absorbance measurement and Raman measurement and other industrial field measurements. It is an industrial grade optical fiber spectrometer with high performance and price.